Product
Setaflash Series 3 Flash Point Tester - 30000-3
The Setaflash Series 3 closed cup flash point tester provides fast and reliable flash point results and requires minimum expertise.
With the Series 3, a test takes less than 2 minutes with just a 2 or 4 ml sample size. A simple user interface with colour digital display and touchscreen icons guides you through the straightforward testing process. For easy record keeping the instrument stores 100,000 test results which can be saved and transferred via a USB port.
Designed for precise and accurate tests, barometric pressure is measured by an internal barometer and correction is automatically applied to the test result. Unknown samples can be tested using ramp mode.
Learn more about flash point testing and which instrument you should be using >
Why flash point autosamplers do not comply with flash point test methods >
Features
- Ambient to 300 °C
- Simple test procedure
- Compact, rugged design
- Automated flash detection
- Ramp mode
- Automatic barometric pressure correction
- USB port and result storage
Information
Details
Ease of use:All functions on the Series 3 including test parameters, instrument status and test results are accessed via the touchscreen display and push button. An audible prompt sounds when a flash is achieved and an automatic flash detector enhances repeatability.
Calibration and verification:
Calibration of the Series 3 can be performed in the field, eliminating the costs and time associated with sending the instrument to a service centre.
Service and maintenance:
The rugged design ensures minimal operational maintenance in needed.
Supplied with: 2 ml syringe, ignitor, Allen key, mains lead, quick start guide and instruction manual
Details
ASTM D3278 | Standard Test Methods for Flash Point of Liquids by Small Scale Closed-Cup Apparatus - paints, enamels, lacquers, varnishes, and related products |
---|---|
ISO 3680 (Obs) | Methods of test for paints. Tests on liquid paints (excluding chemical tests). Test for flash/no flash (rapid equilibrium method) |
ASTM E502 | Standard Test Method for Selection and Use of ASTM Standards for the Determination of Flash Point of Chemicals by Closed Cup Methods |
ISO 3679 | Determination of flash point. Rapid equilibrium closed cup method |
ASTM D3828 | Standard Test Methods for Flash Point by Small Scale Closed Tester |
IP 523 | Determination of flash point. Rapid equilibrium closed cup method |
IP 524 | Methods of test for paints. Tests on liquid paints (excluding chemical tests). Test for flash/no flash (rapid equilibrium method) |
ASTM D7236 | Flash Point by Small Scale Closed Cup Ramp Method |
IP 534 | Flash Point by Small Scale Closed Cup Ramp Method |
ASTM D1655 | Standard Specification for Aviation Turbine Fuels |
CLP Regulations EC No 1272/2008 | European Regulation (EC) No 1272/2008 on classification, labelling and packaging of substances and mixtures |
ASTM D8174 | Standard Test Method for Finite Flash Point Determination of Liquid Wastes by Small-Scale Closed Cup Tester |
EPA 1020 B | Standard test methods for flash point by Setaflash (small-scale) Closed-Cup apparatus |
SW-846 1020C | Standard Test Methods for Flash Point by Setaflash (Small Scale) Closed-Cup Apparatus |
Details
Temperature range | Ambient to 300 °C |
---|---|
Temperature selection | °C or °F |
Heating/cooling method | Cartridge |
Temperature ramp mode | Up to 6 °C/min |
Data storage | 1 GB |
Voltage | 100 to 240 Vac, 50/60 Hz |
Size/Weight | 19.5 cm x 29.5 cm x 14 cm / 3 kg |
CCCN Code | Tariff 90268020 |
Methods
Industries
Spares and accessories for Setaflash Series 3 Flash Point Tester - 30000-3
![LPG Refill Container (pack of 10) - 13666-0 product image](https://www.stanhope-seta.co.uk/wp-content/uploads/13666-0_LPG_Refill_Container-750x750.jpg)
LPG Refill Container (pack of 10) - 13666-0
View accessory![Seta Solid Sample Dispenser - 13747-0 product image](https://www.stanhope-seta.co.uk/wp-content/uploads/13747_LR-750x750.jpg)
Seta Solid Sample Dispenser - 13747-0
View accessory![Seta Metal Cooling Block - 13880-0 product image](https://www.stanhope-seta.co.uk/wp-content/uploads/13880-0_Metal_Cooling_Block.jpg)
Seta Metal Cooling Block - 13880-0
View accessory![Seta Coolant Module - 13870-0 product image](https://www.stanhope-seta.co.uk/wp-content/uploads/13870-0_Seta_Coolant_Module-750x750.jpg)
Seta Coolant Module - 13870-0
View accessory![Power Supply - 30005-0 product image](https://www.stanhope-seta.co.uk/wp-content/uploads/30005-0_Power_Supply-750x750.jpg)
Power Supply - 30005-0
View accessory![Carry Case - 30006-0 product image](https://www.stanhope-seta.co.uk/wp-content/uploads/30006-0_Carry_Case-750x750.jpg)
Carry Case - 30006-0
View accessory![Adaptor – Mains Gas - 30007-0 product image](https://www.stanhope-seta.co.uk/wp-content/uploads/30007-0_Mains_Gas_Adapter-750x750.jpg)
Adaptor – Mains Gas - 30007-0
View accessory![Silicone Rubber Tube 4 metres - 13730-005 product image](https://www.stanhope-seta.co.uk/wp-content/uploads/13730-005_Silicone_Rubber_Tube-750x750.jpg)
Silicone Rubber Tube 4 metres - 13730-005
View accessory![Sample Well O-ring, Viton (Pack of 5) - 13740-004 product image](https://www.stanhope-seta.co.uk/wp-content/uploads/13740-004_Sample_Well_O_Ring-750x750.jpg)
Sample Well O-ring, Viton (Pack of 5) - 13740-004
View accessory![Syringe 4 ml (Small Scale Flash Point Instruments) - 13770-311 product image](https://www.stanhope-seta.co.uk/wp-content/uploads/13770-311_LR-750x750.jpg)
Syringe 4 ml (Small Scale Flash Point Instruments) - 13770-311
View accessory![Sample Well O-Ring, Silicone (Pack of 5) - 13770-004 product image](https://www.stanhope-seta.co.uk/wp-content/uploads/13770-004_Sample_Well_O-Ring-750x750.jpg)
Sample Well O-Ring, Silicone (Pack of 5) - 13770-004
View accessory![Flash Detector Assembly - 13740-425 product image](https://www.stanhope-seta.co.uk/wp-content/uploads/13740-425_Flash_Detector_Assembly-750x750.jpg)
Flash Detector Assembly - 13740-425
View accessory![Syringe 2 ml (Small Scale Flash Point Instruments) - 13740-009 product image](https://www.stanhope-seta.co.uk/wp-content/uploads/13740-009_LR-750x750.jpg)
Syringe 2 ml (Small Scale Flash Point Instruments) - 13740-009
View accessory![Small Scale Certified Flash Point Material (50 ml) - 99879-0 product image](https://www.stanhope-seta.co.uk/wp-content/uploads/99879-0_Small_Scale_Certified_Flash_Point_Material-1-750x750.jpg)
Small Scale Certified Flash Point Material (50 ml) - 99879-0
View accessory![Heat Sink Compound - 13740-017 product image](https://www.stanhope-seta.co.uk/wp-content/uploads/13740-017_Heat_Sink_Compound-750x750.jpg)
Heat Sink Compound - 13740-017
View accessory![Thermometer: Precision Plus Digital - 30008-0 product image](https://www.stanhope-seta.co.uk/wp-content/uploads/30008-0_Digital_Thermometer-e1617961513343-750x758.jpg)
Thermometer: Precision Plus Digital - 30008-0
View accessory![Small Scale Certified Flash Point Material (50 ml) - 99878-3 product image](https://www.stanhope-seta.co.uk/wp-content/uploads/99878-3-LR-1-750x750.jpg)
Small Scale Certified Flash Point Material (50 ml) - 99878-3
View accessory![Portable Digital Barometer - 99910-2 product image](https://www.stanhope-seta.co.uk/wp-content/uploads/99910-2_Digital_Barometer_LR-750x750.jpg)
Portable Digital Barometer - 99910-2
View accessoryDownload product profile
To view our full range of products, download our latest Product Profile here.
![Product profile image](https://www.stanhope-seta.co.uk/wp-content/themes/stanhopeseta/assets/images/product-profile.png)
Want to know more?
View our full range of products, or simply get in contact with us for more information.
![Features equipment](https://www.stanhope-seta.co.uk/wp-content/themes/stanhopeseta/assets/images/global-cta-product@x3.png)