+44 (0)1932 564391

sales@stanhope-seta.co.uk
Find your local representative

FIJI JF - FAME in Jet Instrument

Part Number SA5000-2

The patented Fame In Jet Instrument (FIJI) offers you a rapid and easy check on parts per million (ppm or mg/kg) levels of FAME in aviation fuel.

FIJI uniquely utilises state of the art Fourier Transform Infrared Spectroscopy (FTIR) technology and a patented sample preparation system which allows FAME detection accuracy down to the 10 mg/kg level.

You can use the FIJI as a field or lab based screening tool to give a quick indication of possible FAME contamination that may then require further investigation. You can use the instrument to prevent expensive testing and avoid costly delays of fuel release.

A Multi-Product version of FIJI is available to measure Distillate & Residual Fuels as well as Jet - SA5200-0

If you are an existing users of FIJI Jet, you can upgrade to enable measurement of FAME in Distillate & Residual Fuels in accordance with ASTM D7963 using SA5050-0.



ASTM D1655 now specifies FIJI technology for co-processed Aviation turbine fuel

Calibration and verification equipment availableCalibration and verification equipment available

ADDITIONAL INFORMATION

Ease of use:
The instrument is extremely simple to use and fully automatic, specialist operator training is not required.
The system is self-cleaning, no solvents are required. After each test you simply replace the cartridge and the instrument is immediately ready for the next sample.

Enhanced test throughput:
Tests require less than 50 ml of sample and typically take under 20 minutes.
Results are presented in mg/kg units together with an optional traffic light system for flagging FAME contamination levels of the fuel.
By comparison current analytical tests can take many hours, require complex equipment and demand high skill levels.

Precision and accuracy:
Using a unique sample preparation module the sample is pumped at a controlled flow rate though a proprietary disposable cartridge.
The sample components are analysed by the FTIR and a result is displayed in mg/kg, a graphical spectrum is also shown.

Please note: FIJI IP 583 Starter Kit (SA5001-0) is required for initial operation.

SPECIFICATIONS

Measurement range 10-150 ppm (mg/kg) FAME in Aviation Turbine Fuels
Test duration 20 min
Sample size 50 ml
Operating temperature range 5 to 35 C maximum (80% RH)
Power 50 W maximum
Voltage 100/250 V, 50/60 Hz
Size (HxWxD) 55 x 38 x 42 cm
Weight Approx 20 kg
CCCN Code: Tariff 90273000

DETAILS OF METHODS

ASTM D1655Standard Specificationfor Aviation Turbine Fuels
IP 583Rapid Screening Test for FAME in JET
ASTM D7797Rapid Screening Test for FAME in Aviation Turbine Fuel
FIJI FAME Jet | IP 583

FEATURES

Measures the presence of all FAME types C8 to C22
Approved for co-processed fuels
Analysis time 20 minutes
50 ml sample volume
No hydrocarbon cleaning solvents required
Laboratory and field instrument
Suitable for untrained operators
Patent approved

METHODS

ASTM D1655, ASTM D7797, IP 583

INDUSTRIES

Petroleum - Fuels & Oils

Aviation

Copyright Stanhope–Seta Limited 2014